Looking forward to the future, Linyi Limo Building Materials Co., Ltd. / Rizhao Xianyuan New Material Technology Co., Ltd. will continue to uphold the innovative, pragmatic and enterprising spirit of enterprise, increase research and development investment and market expansion efforts, and continue to introduce more new products and services with market competitiveness. At the same time, the company will also strengthen cooperation and exchanges with well-known enterprises at home and abroad to jointly promote the prosperity and development of the new material technology industry. We have reason to believe that with the joint efforts of all employees, the company's tomorrow will be better!
1. Do I need to deal with it after going to the toilet?
The toilet is equipped with an automatic mixing system, as long as the toilet lid and baffle are closed after use.
2. How often is the storage bin handled? Will it be sticky and smelly?
Biodegradable intelligent toilet, the use of biobacteria to degrade feces, generate water and carbon dioxide gas discharge, will not be sticky without odor. 2-3 people use it every day and replace it once every 30 days or so. If the humidity is too high frequently, press the manual dehumidification button once. The new material can be replaced according to the frequency of use and the state of the fungus material.
3. What should I do if there is too little filler after using it for a period of time?
The filler is usually used for about half a month, and there may be a decrease. Dry materials can. be added appropriately.
4. Can other fillers and bacterial strains be used?
The bacteria used in the biodegradable intelligent toilet are specialized fillers and strains developed specifically for this toilet. If use the other bacteria and fillers cannot achieve the decomposition effect, the consequences will be borne by the user.
5.There is a voice announcement "Hello: the internal probe is wrapped, please power off, clean up and resume use."
After a period of use, if the probe inside the toilet is wrapped with stuffing or the bottom temperature is too high, the toilet will stop running and voice alarm will be given. Please clean the probe with a shovel and resume normal use.
6.The Detection light on the power indicator blinks continuously.
If the indicator continuously blinks, power off and restart. If the indicator continues to blink after restart, contact after-sales personnel.
7.The filling is too high.
If the filler exceeds the mixing teeth, it will cause uneven mixing of the filler in the toilet. It is also possible to stir the filler into the suction of the fan. Part of the filler can be removed for subsequent use.
8.The filling is too low.
(1)After a period of use, the filler has an appropriate reduction and should be added in time.
(2)Open the microbial packing bag and preparation bag, take out the appropriate amount and fill in (according to the packing requirements).
9. Use under power failure.
When the short-time power failure, will not affect the operation of the system, may cause visual pollution and some odor because it can not stir, after the request to manually put a small amount of filler to cover the excrement.
10.Toilet wall, fan and pipeline maintenance.
Power off periodically to clean the stuffing stuck on the inside of the toilet. The exhaust pipe should be regularly maintained and cleaned to avoid affecting the exhaust effect.
11.The fan has been running non-stop.
(1)The optoelectronic switch screws loose caused by sagging is blocked by the toilet lid, appropriate panasonic screws slightly upward lift a certain Angle, re-tighten.
(2) The photoelectric switch is blocked by foreign bodies, clean up foreign bodies.
12.Photoelectric switch failure.
(1)Photoelectric switch as a component to ensure safety, when there is a foreign body occlusion, in addition to the fan work, other actions will not work.
(2)The photoelectric switch is damaged. Notify maintenance personnel to repair.
(3)The photoelectric switch encounters strong light (such as strong sunlight). Look at the source of light and add shades.
13.The toilet has been continuously dehumidifying work; Dust continues to heat up.
(1)Clamping material between humidity sensor probes. Clean the area around the humidity sensor after the toilet is powered off.
(2) Foreign bodies such as wired objects wrap around humidity sensors. Clean the area around the humidity sensor after the toilet is powered off.
(3) The humidity sensor probe is put together. After power failure, clean the toilet around the humidity sensor and separate it lengthwise.Or contact maintenance personnel directly.
14.The motor is not running.
(1)The motor is damaged, contact the maintenance personnel to repair and replace.
(2)Motor line falls off, contact maintenance personnel to repair.
(3) There are foreign bodies in the toilet, find them and remove them.
(4)Photoelectric switch occlusion, clean up foreign bodies.
15.Small wind, condensate or odor.
(1) If the fan is damaged, contact maintenance personnel to replace the fan.
(2)The inner wall of the exhaust pipe adheres to dust, the toilet is powered off and the fan pipe is removed, and the foreign matter in the inner wall is cleaned.
(3) Suction tuyere packing accumulation, power off cleaning.
16. The toilet stops working.
When the toilet appears abnormal in normal operation, endangering the normal use and safe operation of the toilet, it should be shut down immediately, and ask the after-sales personnel to check and repair the toilet. After the completion of fault maintenance, the experiment should be checked, the factors causing the fault should be checked, and the maintenance record should be made. 17.Toilet failure maintenance. When the toilet fails, we should call our company's after-sales phone and contact our after-sales personnel for maintenance.